6. CONNECTION OF I/O UNITS TO
MACHINE INTERFACE
B–63443EN/02
HARDWARE
70
(1) Install the I/O module in a fully enclosed cabinet.
(2) See Section 3.1 for the environment conditions.
Item Specification Remarks
Operator’s panel I/O
module B2
A20B–2002–0521 DI: 48 points
DO: 32 points
MPG interface is not supported.
Fuse (replacement part) A03B–0815–K001 1 A
Item Specification Remarks
DI points 48 points 24 V input
DO points 32 points 24 V source type output
Power Mate interface FANUC I/O Link
connection
Select the built–in I/O card or
the other card type.
Supply voltage Power supply
rating
Heat
output
Remarks
24 VDC "10% is sup-
plied from power supply
connector CPD1. The
tolerance of "10% in-
cludes momentary and
ripple currents.
0.3 A+7.3 mA×DI 7.5+0.175
×DI (W)
DI = number of DI
points in the ON
state
NOTE
Ensure that the maximum current per DOCOM pin (DO
power supply pin) does not exceed 0.7 A.
6.3.10
Specifications
Installation conditions
Ordering specifications
Module specifications
Power supply rating