F. INPUTTING PARAMETERS
B–63443EN/02
APPENDIX
278
Inputting parameters
1 Make sure the input device is ready for reading.
2 Press the EMERGENCY STOP button on the machine operator’s
panel.
3 Press function key
OFFSET
SETTING
.
4 Press the soft key
[SETING]for chapter selection.
5 Enter 1 in response to the prompt for writing parameters (PWE).
Alarm P/S100 (indicating that parameters can be written) appears.
6 Press soft key
SYSTEM
.
7 Press chapter selection soft key
[PARAM].
8 Press soft key
[(OPRT)].
9 Press the rightmost soft key
(next–menu key).
10 Press soft keys
[READ]and[EXEC].
Parameters are read into memory. Upon completion of input, the
”INPUT” indicator at the lower–right corner of the screen disappears.
11 Press function key
OFFSET
SETTING
.
12 Press soft key
[SETING] for chapter selection.
13 Enter 0 in response to the prompt for writing parameters.
14 Turn the power to the Power Mate back on.
15 Release the EMERGENCY STOP button on the machine operator’s
panel.
1 Press the EMERGENCY STOP button on the machine side.
2 Set PWE on the setting screen to 1. Alarm P/S100 is displayed at
this time.
3 The parameter screen is selected by pressing the <PARAM> key.
4 Press the <READ> key.
5 NC parameters are input to the memory by this operation. Normally,
alarm P/S000 will activate after completion of parameter reading.
Normally, P/S alarm 000 is generated after parameters have finished
being read in.
6 Set PWE on the setting parameter to 0.
7 Turn on the Power Mate power again if PS alarm activates.
8 Release the emergency stop button of machine side.
Procedure (CRT/MDI)
Procedure (DPL/MDI)