B–63443EN/02
H. DESCRIPTION OF PARAMETERS
APPENDIX
313
3102 CHI JPN
(Bit)#7 #6 #5 #4 #3 #2 #1 #0
Select the language to be used for the CRT.
If the parameter No.3102 is not set, English is used.
Data type: Bit
JPN Determines whether to use Japanese.
0: Not used
1: Used
CHI Determines whether to use Chinese.
0: Not used
1: Used
NOTE
1 When this parameter is set, turn off the power once. Then
turn it on for machining.
2 Japanese and Chinese can be used only when the
corresponding option is specified.
3104 DAL DRL PPD MCN
(Bit)#7 #6 #5 #4 #3 #2 #1 #0
Data type: Bit
MCN Machine position
0: Not displayed according to the unit of input.
(Regardless of whether input is made in mm or inches, the
machine position is displayed in mm for millimeter
machines, or in inches for inch machines.)
1: Displayed according to the unit of input.
(When input is made in mm, the machine position is
displayed in mm, and when input is made in inches, the
machine position is displayed in inches accordingly.)
PPD Relative position display when a coordinate system is set
0: Not preset
1: Preset
NOTE
When PPD is set to 1 and the absolute position display is
preset by one of the following, the relative position display
is also preset to the same value as the absolute position
display:
1 Manual return to the reference position
2 Setting of a coordinate system by G92
(G50 when G code system A is used.)
H.10
PARAMETERS OF
CRT/MDI, DISPLAY,
AND EDIT