B–63443EN/02
H. DESCRIPTION OF PARAMETERS
APPENDIX
297
Set the F0 rate of the rapid traverse override for each axis.
Rapid traverse override signal
ROV2 ROV1
Override value
0 0 100 %
0 1 50 %
1 0 25 %
1 1 F0
F0:Parameter No.1421
1422 Maximum cutting feedrate for each axis
Data type: 2–word
Unit of data:
Valid data range:
Increment system Unit of data Valid data range
Milimeter machine 1 mm/min 6 to 240000
Inch machine 0.1 inch/min 6 to 96000
Set the maximum cutting feedrate.
1423 Jog feedrate for each axis
Data type: Word axis
Unit of data:
Valid data range:
Increment system Unit of data Valid data range
Milimeter machine 1 mm/min 6 to 15000
Inch machine 0.1 inch/min 6 to 6000
Set the continuous manual feedrate when the override of the jog
feedrate is 100%.
1424 Manual rapid traverse rate for each axis
Data type: 2–word axis
Unit of data:
Valid data range:
Increment system Unit of data Valid data range
Milimeter machine 1 mm/min 30 to 24000
Inch machine 0.1 inch/min 30 to 9600
Set the rate of manual rapid traverse when the rapid traverse override
is 100% for each axis.
NOTE
If 0 is set, the rate set in parameter 1420 is assumed.