B–63443EN/02
12. AUTOMATIC OPERATIONPMC INTERFACE
181
By starting automatic operation during the DNC operation mode (RMT),
it is possible to perform machining (DNC operation) while a program is
being read in via the reader/puncher interface.
To use the DNC operation function, it is necessary to set the parameters
related to the reader/puncher interface in advance.
[Classification] Input signal
[Function] Selects the DNC operation mode (RMT).
To select the DNC operation mode (RMT), it is necessary to select the
memory operation mode (MEM) and set the DNC operation select signal
to “1”.
[Operation] When the DNC operation select signal becomes “1”, the control unit
operates as follows:
– If the memory mode (MEM) has not been selected, the signal is
ignored, and nothing happens.
– If the memory operation mode (MEM) has been selected, the DNC
operation mode (RMT) is selected, and DNC operation becomes
possible. In this case, the DNC operation selection confirm signal
MRMT becomes “1”.
[Classification] Output signal
[Function] Indicates that the DNC operation mode (RMT) has been selected.
[Output condition] The DNC operation selection confirm signal becomes “1” when:
– The DNC operation mode (RMT) is selected.
The DNC operation selection confirm signal becomes “0” when:
– The DNC operation mode (RMT) is not selected.
#7 #6 #5 #4 #3 #2 #1 #0
G043
F003
DNCI
MRMT
#7 #6 #5 #4 #3 #2 #1 #0
12.14
DNC OPERATION
General
Signal
DNC operation select
signal
DNCI<G043#5>
DNC operation selection
confirm signal
MRMT<F003#4>
Signal address