H. DESCRIPTION OF PARAMETERS
B–63443EN/02
APPENDIX
286
NFD Feed before and after the data at data output
0: Output
1: Not output
NOTE
Set NFD to 1 at normal usually.
0102 Number specified for the input/output device (when the I/O CHANNEL is set to 0)
Data type: Byte
Set the number specified for the input/output device used when the
I/O CHANNEL is set to 0, with one of the set values listed in Table
H.2 (a).
Table H.2 (a) Set Value and Specified Number of Input/Output Device
Set value Number specified for input/output device
0 RS232C (For other than the following for example connect to
personal computer etc. , set 0.)
1 Not used
2 Not used
3 FANUC Handy File
4 Not used
5 Not used
6 Not used
0103 Baud rate (when the I/O CHANNEL is set to 0)
Data type: Byte
Set the baud rate of the input/output device used when the I/O
CHANNEL is set to 0, with a set value in Table H.2 (b).
Table H.2 (b) Baud Rate Settings
Set value Baud rate
7 600
8 1200
9 2400
10 4800
11 9600
12 19200