B–63443EN/02
C. 20–PIN INTERFACE CONNECTORS
AND CABLES
APPENDIX
267
Item Unit Specifications
Product No. – A66L–0001–0286
Manufacturer – HITACHI CABLE, LTD.
OKI ELECTRIC CABLE., LTD.
Rating –
80_C, 30V
Material
Conductor,braid–shielded
wire,drain wire
–
Strand wire of tinned annealed
copper (JIS C3152)
Insulator – Heat–resistant flame–retardant vinyl
Sheath – Oilproof, heat–resistant, flame–re-
tardant vinyl
Number of wires (wire ons.) Cores 6 (1 to 6) 6 (three pairs)
(7 to 9)
Con-
Size mm
2
0.5 0.18
ductor
Structure Conduc-
tors
/mm
20/0.18 7/0.18
Outside diameter mm 0.94 0.54
Insula-
tor
Standard thickness
(The minimum thickness is
at least 80% of the stan-
dard thickness.)
mm 0.25 0.2
Outside diameter mm 1.50 0.94
Twisted
Outside diameter mm 1.88
pair
Direction of lay – Left
Pitch mm 20 or less
Lay – Twist the wires at an appropriate
pitch so the outermost layer is right–
twisted, and wrap tape around the
outermost layer.
Apply a cable separator as required.
Lay diameter mm 5.7
Drain
Size mm
2
0.3
wire
Structure Wires/
mm
12/0.18
Outside diameter mm 0.72
Shield
Element wire diameter mm 0.12
braid
Thickness mm 0.3
Braid density % 70
Outside diameter mm 6.3
Sheath
Color – Black
Standard thickness
(The minimum thickness is
at least 85% of the stan-
dard thickness.)
mm 1.1
Outside diameter mm 8.5Max. 9.0(1)
Standard length m 100
Packing method – Bundle
Electri-
cal per-
Electric resistance
(at 20_C) (wire nos.)
W/km 39.4(1 to 6) 113(7 to 9)
for-
mance
Insulation resistance
(at 20_C)
MW–km 15
Dielectric strength (AC) V/min. 500
Flame resistance – Shall pass flame resistance test
VW–1SC of UL standards,
NOTE
The maximum outside diameter applies to portions other
than the drain wire.
12–core cable
D Specifications