B–63443EN/02
H. DESCRIPTION OF PARAMETERS
APPENDIX
303
When the battery of absolute pulse coder is connected at first
time or replace the battery, first rotate the motor through at
least one turn then turn the power off, before returning to the
reference position.
1816 DM3x DM2x DM1x
(Bit)#7 #6 #5 #4 #3 #2 #1 #0
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
Data type: Bit axis
DM1x to DM3x Setting of detection multiply
Set value
DM3x DM2x DM1x
Detection mulyiply
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
1/2
1
3/2
2
5/2
3
7/2
4
NOTE
When the flexibly feed gear is used, do not use these
parameters. Set the numerator and denominator of DMR
to an appropriate values in parameters 2084 and 2085
respectively.
1820 Command multiply for each axis (CMR)
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
Data type: Byte axis
Set a command multiply indicating the ratio of the least command
increment to the detection unit for each axis.
Least command increment = detection unit command multiply
Relationship between the increment system and the least command
increment
Increment system
Least input
increment
Unit
Milimeter machine 0.001 mm
Inch machine 0.0001 inch