B-63443EN/02-2
14/15
EDIT
DATE DESIG. DESCRIPTION
FANUC Power Mate 0 Connection Manual
Addition of external I/O device control Expansion
TITLE
DRAW.NO.
CUST.
SHEET
01
011128 New design
ALARM LIST
Number Message Contents
079 BP/S alarm Contents of programs in NC’s memory do
not coincide with contents of programs
that are read from external I/O device in
the operation of program comparisons.
Confirm the contents of programs in
external I/O device and in NC’s memory.
085 BP/S alarm The overrun error, parity error or flaming
error occurs when the reading through
reader/puncher interface is executed.
The number of bit of inputted data, the
setting of baud rate or the specified
number of the input/output device is
wrong.
086 BP/S alarm The operation preparation signal (DR) of
I/O device is off when the Input/output of
data through reader/puncher interface is
executed.
It is conceivable that the I/O device is
powered off, some cable is broken or
base printed circuit board is broken.
087 BP/S alarm The input of data is not stopped within 10
characters since the stop reading
operation is performed.
The I/O device or the base printed circuit
board is broken.
233 BP/S alarm
Some other user is using the device such
as RS-232-C when you try to use the
device.
239 BP/S alarm In external I/O device control, the
background edition is operated while
some external punch is being operated.