H. DESCRIPTION OF PARAMETERS
B–63443EN/02
APPENDIX
300
1622
Time constant for exponential acceleration/deceleration, or linear accelera-
tion/deceleration after interpolation in cutting feed for each axis.
Data type: Word axis
Unit of data: ms
Valid data range : 0 to 4000
(Cutting feed exponential acceleration/deceleration)
0 to 512
(Linear acceleration/deceleration after cutting
feed interpolation)
Set the time constant used for exponential function acceleration/
deceleration or linear acceleration/deceleration after interpolation in
cutting feed for each axis. Except for special applications, the same
time constant must be set for all axes in this parameter. If the time
constants set for the axes differ from each other, proper straight lines
or arcs cannot be obtained.
1623
FL rate of exponential function acceleration/deceleration in cutting feed for
each axis
Data type: Word axis
Unit of data:
Valid data range:
Increment system Unit of data Valid data range
Milimeter machine 1 mm/min 6 to 15000
Inch machine 0.1 inch/min 6 to 6000
Set the lower limit (FL rate) of exponential function
acceleration/deceleration in cutting feed for each axis. Except for
special applications, this parameter must be set to 0 for all axes. If
a value other than 0 is specified, proper straight lines or arcs cannot
be obtained.
1624
Time constant of exponential function acceleration/deceleration or linear
acceleration/deceleration after interpolation in jog feed for each axis.
Data type: Word axis
Unit of data: ms
Valid data range : 0 to 4000
(Jog feed exponential acceleration/deceleration)
0 to 512
(Linear acceleration/deceleration after jog feed
compensation)
Set the time constant used for exponential function
acceleration/deceleration or linear acceleration/deceleration after
interpolation in continuous manual feed for each axis.