E. DISPLAYING AND SETTING
PARAMETERS
B–63443EN/02
APPENDIX
276
1 Press the <VAR> key to display the settings screen.
2 Use the cursor keys to position the cursor at PWE.
3 Press the <1> key and the <INPUT> key, in that order, to enable
parameters to be written. The CNC unit will generate P/S alarm 100.
4 Press the <DGNOS/PARAM> key to display the parameter screen.
>&0001 00000000
&0002 00000000
5 Move the cursor to the number of the parameter to change.
Method 1
Use the cursor keys. The cursor will continue to move while a cursor
key is being pressed.
Method 2
Press the following keys and enter data in the order shown:
<No.><(parameter No.)><INPUT>
6 Enter a parameter value with the data input keys.
7 Press the <INPUT> key. The parameter value is input and displayed.
8 After all parameters have been set and confirmed, return to the
settings screen and set PWE to 0.
9 Normally, in order to release the alarm state, press the <CAN> key.
However, in order to release alarm No. 000, the power needs to be
turned off and then on again.
Some parameters are not effective until the power is turned off and on
again after they are set. Setting such parameters causes alarm 000. In this
case, turn off the power, then turn it on again.
Some parameters can be set on the setting screen if the parameter list
indicates “Setting entry is acceptable”. Setting 1 for
PARAMETER
WRITE is not necessary when these parameters are set on the setting
screen.
Procedure for DPL/MDI
Explanations
D Parameters that require
turning off the power
D Setting data