10. REFERENCE POSITION RETURN
B–63443EN/02
PMC INTERFACE
164
(2) L
DA
: Distance between deceleration limit switch
released point and reference position
L
DA
: Move amount of 1/2 revolution of motor
Since the above conditions do not include the limit switch
operation variations, this point must also be considered at
installation.
(c) Reference
For the reference position return described above, it is necessary
to move the machine at a feedrate with the servo position
deviation value more than 128 before the first return is done after
turning power on or releasing the emergency stop or servo alarm
state. Here, the servo position deviation value is calculated by the
feedrate and the servo loop gain as follows :
E +
F
G
1
U
E : Servo position deviation value(µm)
F : Feedrate(µm/sec)
U: Detection unit (µm)
G: Servo loop gain
Generally, the detection unit is 1µm.
For example, if the machine is moved at a feedrate of 6
m/min and servo loop gain is 30 at the time, servo position
deviation is
E +
6,000 1,000
60
1
1
30
+ 3, 333
Conversely, when detection unit is 1µm and servo loop gain is 30, the
feedrate with the servo position deviation of 128 is
F = 128 30 60 (mm) = 230,400 (µm/min) = 230 (mm/min)
By the above result, the machine should be moved toward the reference
position at a feedrate of more than 230 mm/min before the first reference
position return is performed.
The servo position error that occurs during actual feeding can be detected
using diagnose 300.