Procedure for enabling/displaying parameter writing
1 Select the MDI mode or enter state emergency stop.
2 Press function key
OFFSET
SETTING
.
3 Press soft key
[SETING] to display the setting screen.
SETTING (HANDY) O0001
N00000
> _
MDI **** *** ***
ALM
[ OFFSET ][ SETING ][ ][ ][ (OPRT
) ]
PARAMETER WRITE = 1 (0:DISABLE 1:ENABLE)
TV CHECK = 0 (0:OFF 1:ON)
PUNCH CODE = 1 (0:EIA 1:ISO)
INPUT UNIT = 0 (0:MM 1:INCH)
I/O CHANNEL = 0 (0–1:CHANNEL NO.)
SEQUENCE NO. = 0 (0:OFF 1:ON)
4 Move the cursor to PARAMETER WRITE using cursor keys.
5 Press soft key
[(OPRT)], then press [1: ON] to enable parameter
writing.
At this time, the CNC enters the P/S alarm state (No. 100).
6 After setting parameters, return to the setting screen. Move the cursor
to
PARAMETER WRITE and press soft key [(OPRT)] , then press
[0: OFF].
7 Depress the
RESET
key to release the alarm condition. If alarm No. 000
has occurred, however, turn off the power supply and then turn it on,
otherwise the alarm is not released.
Procedure for CRT/MDI