12 / 12
EDIT
DATE DESIG. DESCRIPTION
FANUC Power Mate 0 Connection Manual
Addition of Tool geometry and wear offset
TITLE
DRAW.NO.
CUST.
SHEET
01
011129 New design
B-63443EN/02-4
5013 Maximum value of tool wear compensation
[Data type]
Two–word
[Unit of data]
Increment system IS-B Unit
Metric input 0.001 mm
Inch input 0.0001 inch
[Valid data range]
Increment system
IS-B
Metric input 0 to 999999
Inch input 0 to 999999
This parameter sets the maximum value of tool wear compensation. The following
alarm or warning will be informed when the tool wear compensation (absolute value)
exceeding this setting value is set.
Input from MDI Too many digits
Input by G10 P/S 32 offset value is out of range by G10
5014 Maximum value of incremental input for tool wear compensation
[Data type]
Two–word
Increment system IS-B Unit
Metric input 0.001 mm
Inch input 0.0001 inch
Increment system IS-B
Metric input
0
~
999999
Inch input
0
~
999999
This parameter sets the maximum value of tool wear compensation at an incremental
input. If the incremental value exceeds the set value, the following alarm or warning
message is indicated:
Input from MDI Data is out of range
Input by G10 P/S 32 offset value is out of range by G10