H. DESCRIPTION OF PARAMETERS
B–63443EN/02
APPENDIX
296
1401 RDR RFO RPD
(Bit)#7 #6 #5 #4 #3 #2 #1 #0
Data type: Bit
RPD Manual rapid traverse during the period from power-on time
to the completion of return to the reference position
0: Disabled (Manual continuous feed is performed.)
1: Enabled
RFO When cutting feedrate override is 0% during rapid traverse,
0: The machine tool does not stop moving.
1: The machine tool stops moving.
RDR Dry run for rapid traverse command
0: Disabled
1: Enabled
1410 Dry run rate
Data type: Word
Unit of data:
Valid data range:
Increment system Unit of data Valid data range
Milimeter input 1 mm/min 6 to 15000
Inch input 0.1 inch/min 6 to 6000
Set the dry run rate when the jog feedrate is overridden by 100%.
1420 Rapid traverse rate for each axis
Data type: 2–word axis
Unit of data:
Valid data range:
Increment system Unit of data Valid data range
Milimeter machine 1 mm/min 30 to 24000
Inch machine 0.1 inch/min 30 to 9600
Set the rapid traverse rate when the rapid traverse override is 100%
for each axis.
1421 F0 rate of rapid traverse override for each axis
Data type: Word axis
Unit of data:
Valid data range:
Increment system Unit of data Valid data range
Milimeter machine 1 mm/min 6 to 15000
Inch machine 0.1 inch/min 6 to 6000
H.6
PARAMETERS OF
FEEDRATE