9. MANUAL HANDLE FEED
B–63443EN/02
PMC INTERFACE
158
[Classification] Input signal
[Function] This signal selects the distance traveled per pulse from the manual pulse
generator during the manual handle feed or manual handle interrupt. It
also selects the distance traveled per incremental feed step.
The table below lists the signal–to–distance correspondence.
Travel distance select
signal for manual
handle feed
Distance traveled
MP2 MP1 Manual handle feed Incremental feed
0
0
1
1
0
1
0
1
Least input increment 1
Least input increment 10
Least input increment m*
1
Least input increment n*
1
Least input increment 1
Least input increment 10
Least input increment 100
Least input increment 1000
*1 Scale factors m and n are specified using parameter Nos. 7113 and
7114.
WARNING
1 Because the least input increment is used as the units for
manual handle and incremental feed, the same value
represents a different distance depending on whether the
metric or inch input system is used.
2 For an axis under diameter programming, the tool moves by
the diameter value.
#7
G018
#6 #5
HS2B
#4
HS2A
#3 #2 #1
HS1B
#0
HS1A
G019 MP2 MP1
#7
7100
#6 #5 #4
HPF
#3 #2 #1 #0
JHD
[Data type] Bit
JHD Manual handle feed in JOG mode or incremental feed in the manual
handle feed
0: Invalid
1: Valid
9.2
MANUAL HANDLE
FEED AMOUNT
SELECTION SIGNAL
MP1, MP2 <G019#4,
5> (INCREMENTAL
FEED SIGNAL)
Signal address
Parameter