B–63443EN/02
8. INTERLOCKPMC INTERFACE
155
The specified axis movement can be prevented independently by signal
(*ITn).
Parameter(No.3003#2) selects whether axis interlock is enabled or
disabled. Set the parameter to be enabled for axis interlock.
(a) In manual operation
The movement of an interlocked axis is inhibited, but the other axes
are movable. If an axis is interlocked during movement, it stops after
being decelerated, and it starts moving again when it is released from
interlock.
(b)In automatic operation (MEM mode)
If an axis is interlocked while its movement is being commanded (the
move amount is not 0, inclusive of the tool compensation), all axes
movements are prevented.
If a moving axis is interlocked, all axes stop moving after being
decelerated, and they start moving again when it is released from
being interlocked.
*ITn Interlock signal for the nth axis. (n : 1 or 2)
0 : Make it be interlock
1 : Not malce it be interlock
This function is effective during dry run.
8.2
AXIS INTERLOCK
SIGNAL (INPUT) *ITn
<G130#0, #1>