Program errors / Alarms on program and operation (P/S alarm)
Number Message Contents
5312 ILLEGAL COMMAND
IN G10 L75 / 76
The mistake is found in the command format among G11 from G10 L75
/ L76 / L77, or the instruction value exceeds the range of data.
Please modify the program.
5316 TOOL TYPE NUMBER
NOT FOUND
The tool with specified tool type number is not found.
Please modify the program or register the tool.
5317 ALL TOOL LIFE IS OVER The life of all tools with specified tool type number has been reached.
Change the tools.
5318 DIGITIZING PARAMETER ALARM
(M series)
Digitizing probe present signal (PRBST: G006#5) or parameter PRB
(No.0001#5) became 1 when one or some following parameters were
illegal.
Or digitizing function was called through FOCAS1 interface when one or
some following parameters were illegal.
This alarm can be cleared by reset operation.
No.1022,No.1905#6,No.1905#7,No.1910~No.1919,No.1970~No.1979,
No.2016#4,No.2223#1,No.7501#4,No.7501#5,No.7501#6,No.7510,
No.8706#0, No.8706#1
5319 DIGITIZING PROBE IS NOT SET
(M series)
Digitizing function was called through FOCAS1 interface when both
Digitizing probe present signal (PRBST: G006#5) and parameter PRB
(No.0001#5) were 0.
This alarm can be cleared by reset operation.
5320 DIA. / RAD. MODE CAN NOT BE
SWITCHED
In the function of switching the diameter / radius mode, the state of the
input signal for switching the diameter / radius mode has been changed
while the axis which specified the diameter / radius switching is moving.
5322 FAD OF SPINDLE IS INVALID Spindle Fine Acceleration / Deceleration (FAD) is invalid because
spindle amplifier does not support FAD.
Update the spindle amplifier or turn off the parameter of FAD.
5323 SPEED EXCESSIVE ERROR
(T series)
The speed exceeded the value specified in parameter No.1436.
5324 ILLEGAL OPERATION
IN 3D MODE
The manual reference point returned in the
three-dimensional coordinate conversion mode.
5325 SERIAL DCL:
FOLLOW-UP ERROR
1. The amount of follow-up is more than 2147483647 or less than
-2147483648 on detection unit. To reduce the follow-up amount,
please adjust the position where follow-up is begun.
2. The value of parameter (No.1884) is out of range.
5326 SERIAL DCL:
REF-POS ESTABLISH ERR
The amount of movement for establish reference position was
exceeded the amount of parameter (No.14010).
Please try again or change parameter (No.14010) larger.
5327 SERIAL DCL:
MISMATCH (SSYNC CTRL)
(M series)
Master / slave axes of simple synchronized control, one of them is the
linear scale with distance-coded reference marks (serial), and the other
of them is not the linear scale with distance-coded reference marks
(serial). Please establish reference position with the input signal
SYNCJn <G140> setting to zero.
5328 SERIAL DCL:
MISMATCH (ANGL-AXIS)
On angular axis control, one of the angular / perpendicular axes is the
scale with ref-pos, and the other of them is not the scale with ref-pos.
Such system is not admired.
5329 M98 AND NC COMMAND
IN SAME BLOCK
The sub program call (M98) and another NC command were
commanded in the same block during canned cycle.
Modify the program.
5330 G50.9 FORMAT ERROR
(T series)
1. Coordinate value was not commanded at G50.9 block.
2. M code and B code were not commanded at G50.9 block.
3. Improper G-code (G28, etc.) was commanded after G50.9 block.
4. G50.9 block was commanded during canned cycle mode.
5. Three G50.9 blocks were commanded continuously.
5331 ILLEGAL COMMANDED
POSITION (T series)
Moving block has not reached the commanded position. Coordinate
value at G50.9 block or moving command is wrong.
5333 SPINDLE IS BUSY
FOR ANOTHER G96
(T series)
The commanded spindle is busy for constant surface speed control in
another path. Command again after constant surface speed control
mode (G96) is finished.
3/9