APPENDIXA. ALARM LIST
B–63525EN/02
880
Alarm number ContentsFaulty location/corrective action
WN32 LNK CONTROL DATA ER-
ROR
1) Check that the address of
RC_CTLNB_INIT is set for the PMC
system parameter, LANGUAGE ORI-
GIN.
2) Create the link control statement
again.
When a PMC C board is used, link con-
trol statement (program control) data is
invalid.
WN33 LNK CONTROL VER.ER-
ROR
Modify the link control statement in the
PMC C program.
When a PMC C board is used, a link con-
trol statement data edition error has oc-
curred.
WN34 LOAD MODULE COUNT
OVER
Change the number of independent load
modules to eight or less.
When a PMC C board is used, the num-
ber of independent load modules ex-
ceeds eight.
WN35 CODE AREA OUT OF
RANGE
Check the link map and allocate segments
within the range of RAM.
When a PMC C board is used, the code
segment area is out of the range of the
RAM.
WN36 LANGUAGE SIZE ERROR
(OPTION)
1) Reduce the PMC C program.
2) Contact FANUC to specify a PMC C
program option of a larger size.
When a PMC C board is used, the PMC
C program exceeds the size specified for
the PMC C program option.
WN37 PROGRAM DATA ERROR
(LANG.)
Initialize the PMC C program memory.
([EDIT] → [CLEAR] → [CLRLNG] →
[EXEC])
The PMC C program memory must be
initialized.
WN38 RAM CHECK ERROR
(LANG.)
Replace the master printed circuit board. The initialization of the PMC C program
memory failed.
WN39 PROGRAM PARITY
(LANG.)
1) Re–input the PMC C program.
2) Replace the master printed circuit
board.
The parity of the PMC C program parity
is invalid.
WN40 PROGRAM DATA ERROR
BY I/O (LANG.)
Re–input the language program. While the PMC C program was being
read, an interrupt command was gener-
ated.
WN41 LANGUAGE TYPE UN-
MATCH
1) Re–input the PMC C program.
2) Replace the master printed circuit
board.
When a PMC C board is used, an unus-
able C program is input.
WN42 UNDEFINE LANGUAGE
ORIGIN ADDRESS
1) On the PMC system parameter
screen, click [ORIGIN].
2) Set the PMC system parameter, LAN-
GUGE ORIGIN, to the address indi-
cated by the RC_CTLB_INIT in the
map file.
When a PMC C board is used, the PMC
parameter, LANGUAGE ORIGIN, is not
set.
WN48 UNAVAIL LANGUAGE BY
CNC UNMATCH
Remove the PMC C board. A PMC C board is installed in a CNC in