8. EMBEDDED ETHERNET FUNCTION
B–63525EN/02
610
Display item and setting items
The item related to the embedded Ethernet function is displayed.
Item Description
MAC ADDRESS Embedded Ethernet MAC address
Set the TCP/IP–related items of the embedded Ethernet.
Item Description
IP ADDRESS Specify the IP address of the embedded Ethernet.
(Example of specification format: ”192.168.1.1”)
SUBNET MASK Specify a mask address for the IP addresses of the network.
(Example of specification format: ”255.255.255.0”)
ROUTER IP
ADDRESS
Specify the IP address of the router.
Specify this item when the network contains a router.
(Example of specification format: ”192.168.1.254”)
Set the items related to the host computer with which the FACTOLINK
server operates.
Item Description
IP ADDRESS Specify the IP address of a personal computer to be accessed
by the FACTOLINK function.
(Example of specification format: ”192.168.1.100”)
PORT NUMBER Specify a port number to be used with the FACTOLINK function.
The valid input range is 5001 to 65535.
A specified port number must match ”ocsnc” of the ”services”
file of the personal computer.
For details, refer to ” FANUC FACTOLINK Script Function OP-
ERATOR’S MANUAL (B–75054EN)”.
Display item related to
the embedded Ethernet
function
Embedded Ethernet
TCP/IP setting items
FACTOLINK setting
items