7. INTERFACE BETWEEN CNC AND PMC
B–63525EN/02
480
Trigger position
<– 1 second –><–––– 9 seconds ––––>
|| |
–1 0 9 (SEC)
(i) Sampling condition
This item becomes settable when “signal transition” is selected as the
trace stop condition. Set a condition for sampling.
D Trigger: Sampling is performed when a sampling trigger
condition is satisfied.
D Transition: Sampling is performed when the signal at the sampling
address makes a transition.
(j) Sampling condition/trigger/address
This item becomes settable when “signal transition” is selected as the
sampling mode and “trigger” is selected as the sampling condition.
Set a sampling trigger address.
(k)Sampling condition/trigger/mode
This item becomes settable when “signal transition” is selected as the
sampling mode and “trigger” is selected as the sampling condition.
Set a trigger condition mode.
D Rising: Sampling is performed on a rising edge of the trigger
signal.
D Falling: Sampling is performed on a falling edge of the trigger
signal.
D Transition: Sampling is performed when the trigger makes a
transition.
D On: Sampling is performed when the trigger signal is on.
D Off: Sampling is performed when the trigger signal is off.