7. INTERFACE BETWEEN CNC AND PMC
B–63525EN/02
466
4 [EDIT] Calling the ladder diagram editing screen
This soft key switches the screen display to the ladder diagram
editing screen. This soft key is displayed only when the
programmer function is enabled. While the online monitor
function is enabled, the screen display can be switched to the ladder
diagram editing screen. If a password is set for the ladder program,
the input of the password is requested. Enter the password required
for editing.
5 [SWITCH] Calling the selection monitor screen
This soft key displays the selection monitor screen.
6 [SETING] Screen setting
This soft key calls the setting screen for the ladder diagram display
screen. Various settings for ladder diagram display can be
modified. To return to the ladder diagram display screen, use the
return key [<]. For details of the setting screen, see “Screen setting”
in the description of the ladder diagram display screen.
Title information (details)
Total number of programs
Program subject to manipulation
Key input line
Message display line
List display area
Detail display screen
7.3.3.2
Program list display
screen