B–63525EN/02
1. DISPLAY AND OPERATION
143
If an alarm is issued during operation, the group number of the slave
causing the alarm is indicated at the right end of the message field on the
screen. Check the details on the alarm screen. For example, (13) means
that the first and third power motion units are in the alarm state.
1. Press the [MSG] function selection soft key. Just the error code is
displayed on the screen.
POWER MOTION MANAGER
ALARM
1.GROUP0 / β
442 210 232
[ POS ][ ][ ][SYSTEM ][ MSG ]
Up to forty codes can be displayed on the screen.
For details of the alarm, refer to the connection manual of the
corresponding Power Motion unit.
The active slave is subjected to the ZOOM function, which will be
described later, and parameter overwrite. The title of the active slave is
displayed in a color different from the display color of the other slave
titles.
The active slave can be selected by pressing the [±NEXT] or [°BACK]
soft key, which is displayed after the continuous menu key
is
pressed several times.
[±NEXT]: Displays the screen of the Power Motion unit connected after
the currently active slave. The equipment other than the
Power Motion unit is ignored.
[°BACK]: Displays the screen of the Power Motion unit connected
before the currently active slave.
Whether the screen displays the data of just a single unit or of four units
in four segments is specified in the SLV bit (bit 0 of parameter 960).
To switch the four–slave display to the single–slave display, press the
[ZOOM] soft key, which is displayed after the continuous menu key
is pressed several times. The single–slave display shows the data of the
active slave. To switch the single–slave display to the four–slave display
showing the data of four slaves including the active slave, press the
[ZOOM] key.
D Alarm screen
D Operating the active
slave
D Single–slave display/
Four–slave display