OPERATION
11. SETTING AND DISPLAYING DATA
B–63534EN/02
1076
Procedure for displaying the fixture offset screen and setting data on the screen
1 Press function key
OFFSET
SETTING
.
2 Press continuous menu key
several times until [F–OFS]
appears.
3 Press soft key
[F–OFS].
The following fixture offset screen appears:
FIXTURE OFFSET
NO.01
X 0.000
Y 0.000
Z 0.000
C 0.000
B 0.000
A 0.000
[NO.SRH] [ ] [ PUNCH ] [ +INPUT ] [ INPUT ]
NO.02
X 0.000
Y 0.000
Z 0.000
C 0.000
B 0.000
A 0.000
On this screen, eight groups of fixture offset values can be set and
checked.
Press soft key
[(OPRT)] to display the above operation soft keys.
– Use the page and cursor keys, and soft key
[NO. SRH] to place the
cursor at a desired item to be set.
– Enter data, then press soft key
[INPUT].
– To add a value to already set data, press soft key [+INPUT].
The displayed data is now changed to the set data.
Data can also be set using the INPUT MDI key.
NO. 01 to NO. 08 indicates the number of a group of fixture offset values.
There are eight groups. Soft key
[NO. SRH] can be used to search for a
desired group number.
Soft key
[PUNCH] can be used to output fixture offset values to an
external device. For details of the output format and how to input data,
see Section II.14.14, “ROTARY TABLE DYNAMIC FIXTURE
OFFSET,” in this manual.
Procedure
Explanations
D Entering numeric values
D Number of groups of
fixture offset values
D Outputting fixture offset
values
F OFFSET