OPERATIONB–63534EN/02 8. DATA INPUT/OUTPUT
939
Operation history data output
The file (operation history data) in the CNC memory can be output to the
host computer.
1 Place the CNC in the EDIT mode.
2 Press the function key
SYSTEM
.
3 Press the continuous menu key at the right end of the soft key display.
4 Press the [OPEHIS] soft key. The operation history screen appears.
5 Press the [(OPRT)] soft key.
6 Press the continuous menu key at the right end of the soft key display.
7 Press the [PUNCH] soft key.
8 Press the [EXEC] soft key.
9 During output, “OUTPUT” blinks in the lower–right corner of the
screen.
The fixed file name HISTORY is used.
Refer to the operator’s manual of each CNC.
The host computer to which the FTP file transfer function attempts to
make a connection as the current communication destination can be
checked.
1 Press the function key
PROG
.
2 Press the continuous menu key at the right end of the soft key display.
3 Press the [CONECT] soft key. The connection host change screen
appears. The Ethernet functions currently available are displayed.
Procedure
File name
File format, restrictions
8.12.1.7
Checking and changing
of the connection host
Procedure