OPERATION
B–63534EN/02
11. SETTING AND DISPLAYING DATA
1085
By pressing the function key
MESSAGE
, data such as alarms, alarm history
data, and external messages can be displayed.
For information relating to alarm display, see Section III.7.1. For
information relating to alarm history display, see Section III.7.2.
For information relating to external message display, see the relevant
manual supplied by the machine tool builder.
External operator messages can be preserved as history data.
Preserved history data can be displayed on the external operator message
history screen.
Procedure for external operator message history display
1 Press the
MESSAGE
function key.
2 Press the continuous menu key
, then press the chapter selection
soft key
[MSGHIS]. The screen shown below appears.
MESSAGE HISTORY O0000 N00000
01/09/12 17:25:00 PAGE:1
NO. ****
MEM STRT MIN FIN ALM 09:36:48
[][ MSGHIS ] [ ] [ ] [ (OPRT) ]
Date and Page number
Message nuumber
Display range
(Up to 255 characters)
NOTE
Up to 255 characters can be specified for an external
operator message. By setting MS1 and MS0 (bits 7 and 6
of parameter No. 3113), however, the number of characters
that can be preserved as external operator message history
data can be restricted, and the number of history data items
selected.
When an external operator message number is specified, updating of the
external operator message history data is started; this updating is
continued until a new external operator message number is specified or
deletion of the external operator message history data is specified.
11.7
SCREENS
DISPLAYED BY
FUNCTION KEY
#MESSAGE#
MESSAGE
11.7.1
External Operator
Message History
Display
Procedure
MSGHIS
Continuous menu key
Explanations
D Updating external
operator message
history data