OPERATION6. SAFETY FUNCTIONS
B–63534EN/02
856
(I,J,K)
(X,Y,Z)
X>I, Y>J, Z>K
X–I >ζ (In least command increment)
Y–J >ζ (In least command increment)
Z–K >ζ ((In least command increment)
G 22X_Y_Z_I_J_K_;
ζ (mm)=
7500
F
F=Rapid traverse speed (mm/min)
Fig. 6.3 (b) Creating or changing the forbidden area using a program
When setting the area by parameters, points A and B in the figure below
must be set.
B (I,J,K)
A (X,Y,Z)
X>I, Y>J, Z>K
X–I >ζ (In least command increment)
Y–J >ζ (In least command increment)
Z–K >ζ ((In least command increment)
ζ (mm)=
7500
F
F=Rapid traverse speed (mm/min)
Fig. 6.3 (c) Creating or changing the forbidden area using a parameters
In stored stroke check 2, even if you mistake the order of the coordinate
value of the two points, a rectangular, with the two points being the
apexes, will be set as the area.
When you set the forbidden area through parameters (Nos. 1322, 1323),
the data should be specified by the distance from the machine coordinate
system in the least command increment. (Output increment)
If it is set by a G22 command, specify the data by the distance from the
machine coordinate system in the least input increment (Input increment.)
The programmed data are then converted into the numerical values in the
least command increment, and the values are set as the parameters.
Set the boundary with parameters No. 1324 and 1325. The area inside the
boundary becomes the forbidden area.