OPERATION
B–63534EN/02
3. MANUAL OPERATION
783
NOTE
When an alarm state exists, data cannot be set.
5 Press the cycle start switch on the machine operator’s panel to start
command execution. The status is indicated as ”MSTR.” (When the
9” screen is being used, the actual feedrate ”ACT.F” and spindle
speed ”SACT” appear on the key input line.) The automatic operation
signal, STL, can be turned on by setting bit 2 (JST) of parameter No.
7001.
JOG
MSTR *** MTN
00 : 00 : 00
ACT.F 1000 SACT 0
~~
~~
NOTE
If the cycle start switch is pressed while an alarm state
exists, a ”START IMPOSSIBLE” warning is generated, and
the entered data cannot be executed.
6 Upon the completion of execution, the ”MSTR” status indication is
cleared from the screen, and automatic operation signal STL is turned
off. The set data is cleared entirely. G codes are set to G00 or G01
according to the setting of bit 0 (G01) of parameter No. 3402.
An amount of travel is given as a numeric value, preceded by an address
such as X, Y, or Z. This is always regarded as being an incremental
command, regardless of whether G90 or G91 is specified.
The tool moves along each axis independently at the rapid traverse rate.
Linear interpolation type positioning (where the tool path is linear) can
also be performed by setting bit 1 (LRP) of parameter No. 1401.
Manual rapid traverse selection switch
Off On
Feedrate
(parameter)
Jog feedrate for each axis
(No. 1423)
Rapid traverse rate for each
axis
(No. 1420)
Automatic
acceleration/
deceleration
(parameter)
Exponential acceleration/
deceleration in jog feed for
each axis
(No. 1624)
Linear acceleration/
deceleration in rapid traverse
for each axis
(No. 1620)
Override Manual feed override Rapid traverse override
Explanations
D Positioning