2.DEVELOPMENT OF CUSTOM SCREEN B-66284EN/01
- 98 -
2.3.3
Screen Structure Definition Control
The screen structure definition control provides two types of
specification: setting of a combination of sub screens to make up a
single screen (base screen) and definition of a popup screen. Only a
single instance of this control can be placed in a form. More than one
instance cannot be placed.
As an option function, this control provides a data change report
function.
Definition of a Base Screen and Sub Screens
FANUC PICTURE allows you to create part of a screen as a sub
screen and switch this sub screen to another sub screen. With this
specification, define the combination of sub screens to make up a base
screen.
The items to be set in the properties of this control are the name of the
base screen and the name of the first of the sub screens to make up the
base screens (i.e., the name of the first sub screen to be displayed after
the power is turned on of all the sub screens to be displayed
alternately in the same section on the base screen). On the first sub
screen specified here, place a sub screen switch button and specify the
next page sub screen. By calling a still another sub screen from the
called sub screen, sub screen switching is accomplished.
On a single base screen, up to five sub screens may be displayed at the
same time. That is, it is possible to create up to five partitions within
the range of the screen resolution and switch screens between the
partitions.
For the screen structure example shown below, set the underlined
screen names as the names of the first sub screens in the properties of
the screen structure definition control.
BASE1 (base screen name)
SUB10
→ SUB11 → SUB12 (→ To SUB10)
SUB20 → SUB21 (→ To SUB20)
(*) Up to five sub screens can be specified for
simultaneous display.
Place the control in the valid area within the range of the screen
resolution.
Popup Screen Definition
Place the control in the valid area on the screen and expand it to the
size of the rectangle used as a popup screen. Then, check Popup
Screen, which is one of property items, to specify it as the pop-up base
screen. The size and coordinates of the rectangle to pop up are
determined by pasting this control. In this rectangle, place the
necessary buttons and lamps to create a popup screen.
To return to the screen from which the popup screen was called, create
on the popup screen a button for which “popup erasure” is specified as
the “screen type” of the screen switch control. Clicking this screen
switch button allows you to return to the screen from which the popup
screen was called.