2.DEVELOPMENT OF CUSTOM SCREEN B-66284EN/01
- 38 -
<4> In the Screen Number pull-down list box, specify a CNC screen
to be replaced. For a screen number with the “C Executor”
comment, the screen displayed on the CNC remains to be
unchanged, and a free screen soft key is assigned. (For CNC
units and available screen numbers, see APPENDIX B, "CNC
SCREEN NUMBERS".)
<5> In Key Caption, set a character string to be displayed for the
CNC screen soft key. Specify a half-size alphanumeric character
string in uppercase no longer than six characters.
<6> Check Select flag to enable calling from the CNC screen.
CAUTION
Select flag must be specified at least once in the
base screens including [RETURN].
<7> Making of backup to F-ROM
Checking the [Making of backup to F-ROM] check box causes
the custom screen data in the project contained in the folder on
the personal computer to be saved in a memory card format file.
This enables you to restore the project on the personal computer
by sucking up FANUC PICTURE screen data (this screen data
MEM file usually assumes a file name of FPF0FPDT or
CEX0FPDT) from the F-ROM of the CNC control unit to the
memory card when altering the custom screen of the machine.
If you select [Making of backup to F-ROM] for the custom
screen data for the project, collect the following data into the
specified subfolders. When the custom screen data for a project
that has been saved, the same subfolders are created.
1. Image file data → (project-folder-name)\PhotoData
2. VTS message file data → (project-folder-name)\VtsData
For an explanation of the method of sucking up a screen data
MEM file from the F-ROM of the CNC control unit and
restoring a project on the personal computer, see the explanation
of “New Project”.