2.DEVELOPMENT OF CUSTOM SCREEN B-66284EN/01
- 196 -
Signal Bit:
Specify the signal bit of the signal used to specify whether to
display the character string.
Interlock:
Check this check button to interlock the function for calling a
popup screen in which a keyboard for changing the character
string in the PMC area is placed. Specify the following three
options.
Interlock PMC Area:
Specify the signal area of the popup screen call interlock signal.
The following areas can be specified:
R, D, K, X, Y, G, F, E(PMC-SB7)
Interlock PMC Address:
Specify the signal address of the popup screen call interlock
signal.
Interlock PMC Bit:
Specify the bit position of the popup screen call interlock signal.
Popup Screen Name:
Specify the name of the popup screen in which the keyboard for
changing the character string in the PMC area is placed.
Use Key-in-buffer:
Check this box to input a rewritten character string by using the
key-in-buffer control placed on the same screen, instead of using
the popup screen name mentioned above. Among these rewrite
measures, this check has priority.
* When a PMC character string is to be just displayed and need not
be rewritten, leave Popup Screen Name unspecified, and uncheck
Use Key-in-buffer. When these settings are made, input
operation is disabled even if the control is touched.
Discriminative number:
To use the data change report function, set the number used to
identify this control in the range of 1 to 4095. The identification
number must be unique within the project.
If the data change report function is not used, set zero.