B-66284EN/01 2.DEVELOPMENT OF CUSTOM SCREEN
- 85 -
Control Operating function Touch panel operation
MDI key
operation
Causes the input screen to appear. Touch the target control. Any key
Display the focus. (No operation)
Any of the four
cursor key
Move the focus. (No operation)
Any of the four
cursor key
Erase the focus. (No operation) CAN
Control with input
(By pop-up Ten-Key)
Manually disable continuous input. KEYCLR button DELETE
*1 If there are characters in the key-in buffer, the last one of them is
erased.
Continuous input disabling procedure
The following table lists the procedure for manually disabling
continuous input.
Control with input Continuous input disabling procedure
<1> Input to a key-in buffer control
Key-in buffer controls are usually in a continuous-input state.
Continuous input is disabled by touching a control having the focus or
using the CAN key.
Numeric Indication
Control with Key Input
or
PMC Area Character
String Indication Control
<2> Input by calling a pop-up screen
Continuous input is disabled by erasing the pop-up screen rather than
performing input equivalent to [INPUT], which is a data input method for
the pop-up screen. To erase the pop-up screen, touch the erase button
for it or a shortcut key assigned to the erase button.
Numeric Indication
Control for Calling
Ten-Key Pad
Continuous input is disabled by erasing the pop-up ten-key pad. To erase the
pop-up ten-key pad, touch the [KEYCLR] or the [☒]button for it, or press the
DELETE key.