B-66284EN/01 3.FP FUNCTIONS
- 317 -
-1 Attempted to execute this function while the other
low-speed window function is being executed.
Retry after completing currently executed window’s
process.
1.44 Reading modal data
16
i 18i 21i PMi-D PMi-H 30i 31i 32i
Support CNC
○ ○ ○ ○ ○ ○ ○ ○
○:available
-:unavailable
[Function name]
rdmodal
[Data type]
6: String
[Format/with arguments]
rdmodal[type_block_inp_pmc_address]
[Arguments]
type Kind of modal data
0,..,99 : G code group number
100,.. : modal address
type Address
100: B (2nd auxiliary function)
101: D
102: - (reserved)
103: F
104: H [M]
105: L
106: M
107: S
108: T
109: R [M]
110: P [M]
111: Q [M]
112: M (2nd M code)
113: M (3rd M code)
[M] is read as a modal data on Machining center system
and a commanded data on Lathe system.
block Objective block
0 : Currently executed block
1 : Next block
2 : Next to next block
inp Display type by presence of instruction
0 : Modal information is displayed regardless of the
presence of the buffering and the instruction.
1 : Modal information is displayed when there is an
instruction in the buffered block.
pmc Kind of PMC address for processing result notification
5 : R
9 : D
12 : E (PMC-SB7, PMC for Series 30i)
99 : Processing result is not notified