B-66284EN/01 2.DEVELOPMENT OF CUSTOM SCREEN
- 195 -
- Action
PMC Message Area:
Specify which area of the PMC the character string to be
displayed is located.
Usually, the area to be specified is “D” or “R” or “E”
(PMC-SB7).
PMC Message Address:
Specify the start address of the character string in the area
specified above.
PMC Message Bit:
If specifying “A” for PMC Message Area, specify the character
string registration bit.
PMC Char Count:
Specify the number of bytes of the character string to be
displayed.
Look Signal:
Check this check box to display the character string in the PMC
area only if the specified PMC signal is on. To use this option,
specify the following three options. Character display or display
character erasure is performed by looking at the signal for
changes and, therefore, the signal change state must be retained
for 500 msec or longer.
Signal Area:
Specify the signal area of the signal used to specify whether to
display the character string. The following area can be specified:
R, D, K, X, Y, G, F, A, E(PMC-SB7)
Signal Address:
Specify the signal address of the signal used to specify whether
to display the character string.