2.DEVELOPMENT OF CUSTOM SCREEN B-66284EN/01
- 208 -
- NoAction Image
NoAction signal:
Check this check box to use the embedded-plug-style indication
by an invalid signal. This function disables the function of the
button control and displays the embedded plug style when the
invalid signal specified in the following boxes is detected during
power-up.
When this check box is checked, the following items can be set.
Image File Name:
This box can be used to select the FIG file that contains the
embedded plug styles used when the button control is in the
invalid state.
Style:
Select the type of the embedded plug styles registered in the file
specified in [Image File Name]
State Color:
Select the color of the indicator lamp section.
Border Color 1:
Select the color of the upper and left ends of the button.
Border Color 2:
Select the color of the lower and right ends of the button.
PMC Area
Specify the type of the PMC address of the invalid signal. The
following areas can be specified.
R, D, K, X, Y, G, F, E(PMC-SB7)