2.DEVELOPMENT OF CUSTOM SCREEN B-66284EN/01
- 26 -
PMC type:
Select the PMC type used in the target CNC system from the
following:
3Xi(PMC for Series 30i)
PMC/SB7
PMC/SB6
PMC/SB5
PMC/SD7
Display unit type
Resolution:
Choose whether the display unit of the target CNC is based on
VGA (640×480 pixels) or XGA (1024×768 pixels).
Font:
Select a font size used for CNC display. One of the following
two types, usually called 14” type and 9” type, can be selected:
Small(14inc)
Big(9inc)
Soft key:
If you turned it on, specify the number of soft keys to be used:
Specify how many soft keys the display unit uses.
This setting is referenced in specifying the font and size of
characters in button and lamp captions on a form during screen
editing and in creating screen data related to soft keys.
5 + 2 pieces (Display unit of alias nine inches)
10 + 2 pieces (Display unit of alias 14 inches)
10 + 2 +9 pieces (Display unit with vertical software key for
Series 30i)
Call key to input pop-up screen
Creating screens for a non-touch panel display unit requires
setting up this item.
To input data for a control with input, use one of the following
three input methods: Key-in buffer, pop-up ten-key pad, and
pop-up screen for data input. For the latter two input methods
(pop-up type input methods), a pop-up screen for data input is
called by touching a control with input on a touch panel display
unit. For a non-touch panel display unit, a pop-up screen is called
using a key rather than touching the control. A key for calling a
pop-up screen for data input is selected and set up for an
individual control with input. The following keys can be used for
this purpose.
Numeric keys (0, 1, 2, 3, 4, 5, 6, 7, 8, 9, +, -, .)
Alphanumeric character keys (including numeric keys and
special character keys as well letter keys)
F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, FR, FL (F6 - F10
cannot be specified if the number of soft keys to be used is
5+2.)
VF1, VF2, VF3, VF4, VF5, VF6, VF7, VF8, VF9 (vertical
software key)