10.TOOL FUNCTION B-63783EN-1/01
- 996 -
#7 #6 #5 #4 #3 #2 #1 #0
7401 TRU TRS LFV EMD CT2 CT1
[Input type] Parameter input
[Data type] Bit
#
# #
# 0
00
0CT1
CT1CT1
CT1
#
# #
# 1
11
1CT2
CT2CT2
CT2 A tool change type is set according to the following tables:
- Tool life management
CT2 CT1 Tool Description
(#1) (#0) change
type
Tool group number
specified in the block that
specifies the tool change
command (M06)
Tool life management
count timing
0 0 A Group of tools
already used
01 B
10 C
Life counting is performed for a tool
in the specified tool group when M06
is specified next.
11 D
Tool group to be used
next
Life counting is performed when a
tool in the tool group specified in the
block that specifies M06 is specified.
# 2
# 2 # 2
# 2 EMD
EMDEMD
EMD Specifies when the asterisk (*) for representing the expiration of life is
displayed.
0: Displayed when the next tool is used.
1: Displayed when the life has expired.
# 3
# 3 # 3
# 3 LFV
LFVLFV
LFV Specifies whether life count override is valid.
0: Not valid.
1: Valid.
# 5
# 5 # 5
# 5 TRS
TRSTRS
TRS Specifies that the tool change reset signal (TLRST) is valid when RST is
not set to 1 for a reset, and:
0: When the reset state is set (OP is set to 0).
1: When the reset state is set (OP is set to 0), the automatic operation
stop state is set (STL and SPL are set to 0, and OP is set to 1), or the
automatic operation halt state is set (STL is set to 0, and SPL is set to
1). (However, TLRST is invalid in the automatic operation stop
state, automatic operation halt state, and automatic operation start
state (with STL set to 1) during data setting command (G10 L3)
execution.)