9.SPINDLE FUNCTION B-63783EN-1/01
- 950 -
5980 Grid shift value for orientation
[Input type] Parameter input
[Data type] Integerspindle
[Unit of data] detection unit
[Valid data range] -2048 - 2048
Set a grid shift value from the orientation stop position of the analog
spindle in the servo mode (rigid tapping, spindle positioning, and so
forth).
- For serial spindles
#7 #6 #5 #4 #3 #2 #1 #0
3000 SVO
[Input type] Parameter input
[Data type] Bitspindle
# 4
# 4 # 4
# 4 SVO
SVOSVO
SVO Direction of reference position return in servo mode (rigid tapping, spindle
positioning, and so forth)
0 : The spindle returns to the reference position counterclockwise (viewed
from the motor output axis).
1 : The spindle returns to the reference position clockwise (viewed from
the motor output axis).
NOTE
The orientation (reference position return) direction of
spindle positioning using a serial spindle depends on
the specification of this parameter.
3044 Proportional gain of the velocity loop in servo mode
/synchronization control mode (high-speed gear)
[Input type] Parameter input
[Data type] Integerspindle
[Unit of data] 0.01/sec
[Valid data range] 0 to 32767
Set the proportional gain of the velocity loop for the high-speed gear in the servo
mode (rigid tapping, spindle positioning, and so forth).