12.DISPLAY/SET/EDIT B-63783EN-1/01
- 1338 -
# 4 ATL Specifies whether to allow the abnormal load detection alarm threshold
value to be changed on the fine torque sensing torque graph screen as
follows:
0: Do not allow.
1: Allow.
When this bit is 1, the abnormal load detection alarm threshold value
can be changed on the fine torque sensing graph screen, and the change
is reflected to parameter No. 1997 (servo axis) or 3341 (spindle).
4670 Fine torque sensing target axis 1
4671 Fine torque sensing target axis 2
4672 Fine torque sensing target axis 3
4673 Fine torque sensing target axis 4
[Input type] Parameter input
[Data type] Integer
[Valid data range] -4 to 24
These parameters specify the target axes for the fine torque sensing
function. For a servo axis, its controlled axis number is specified
within a range between 1 and the largest number of controlled axes.
For a spindle, the algebraic sign of the spindle axis number is inverted,
and the spindle number is specified in a range between -1 and -n (where
n is the largest number of controlled spindles).
NOTE
1 If a fine torque sensing target axis, N, is specified as
0, target axis N+1 and those that follow it are ignored
and assumed to be 0.
2 If a servo axis is a target axis for fine torque sensing,
it is necessary to set bit 0 of parameter No. 1958 for
the target controlled axis to 1. If this parameter is 0
for a controlled axis, the torque sensing command
signal does not work for that controlled axis.