B-63783EN-1/01 1.AXIS CONTROL
- 137 -
- Axis setting screen
The axis setting screen displays the information shown below:
Fig. 1.5.3 (e)
The axis setting screen displays the following items:
• AXIS NO.
This item is the placing of the NC controlled axis.
• NAME
This item indicates the name of the corresponding controlled
axis.
• AMPLIFIER
Type of the amplifier connected to each axis
• M1
This item is the number of the connector for pulse module 1,
specified in parameter No. 1094.
• M2
This item is the number of the connector for pulse module 2,
specified in parameter No. 1095.
• 1DSP
This item is the value specified in bit 0 (parameter 1DSP) of
parameter No. 1092. It is 1 for an axis (such as a learning
control axis, high-speed current loop axis, or high-speed
interface axis) that exclusively uses a DSP, which is usually
shared by two axes.
• SPOS
Parameter (No.1027) The value set in parameter No. 1027 is
displayed. A value other than 0 is displayed for a controlled
axis for spindle positioning.
• CS
This item is the value specified in parameter No. 1028. It is 1