1.AXIS CONTROL B-63783EN-1/01
- 30 -
- Minimum value
5290 Minimum value of the operating range of the 1-st position switch (PSW201)
5291 Minimum value of the operating range of the 2-nd position switch (PSW202)
5292 Minimum value of the operating range of the 3-rd position switch (PSW203)
5293 Minimum value of the operating range of the 4-th position switch (PSW204)
5294 Minimum value of the operating range of the 5-th position switch (PSW205)
5295 Minimum value of the operating range of the 6-th position switch (PSW206)
5296 Minimum value of the operating range of the 7-th position switch (PSW207)
5297 Minimum value of the operating range of the 8-th position switch (PSW208)
5298 Minimum value of the operating range of the 9-th position switch (PSW209)
5299 Minimum value of the operating range of the 10-th position switch (PSW210)
[Input type] Parameter input
[Data type] Real
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table(A))
(When the increment system is IS-B, -999999.999 - +999999.999)
Set the minimum value of the operating range of the first to tenth position switches.
NOTE
1 For a diameter-specified axis, use radius values to specify the
parameters used to set the maximum and minimum values of an
operating range.
2 The position switch function is enabled upon completion of
reference position return.