B-63783EN-1/01 7.FEEDRATE CONTROL/ACCELERATION AND DECELERATION CONTROL
- 737 -
6737 Optimum torque acceleration/deceleration (acceleration at P5 during
movement in - direction and deceleration)
[Input type] Parameter input
[Data type] Integer axis
[Unit of data] 0.01%
[Valid data range] 0 to 32767
For each movement direction and for each of acceleration and deceleration, set the
permissible accelerations at acceleration setting points P0 to P5. The permissible
accelerations must be the ratios to the setting of the reference acceleration
parameter (No. 1671). If 0 is set, 100% is assumed.
1671 Per-axis maximum permissible acceleration of before-interpolation
acceleration/deceleration for linear type rapid traverse
or reference permissible acceleration of optimum torque
acceleration/deceleration
[Input type] Parameter input
[Unit of data] Real axis
[Unit of data] mm/sec/sec, inch/sec/sec, degrees/sec/sec (machine unit)
[Minimum unit of data]Follows the increment system of the axis.
[Valid data range] See the standard parameter setting table (D).
(For IS-B and millimeter machines, 0.0 to +99999.999; for inch machines,
0.0 to +9999.9999)
(1) Set the maximum permissible acceleration of before-interpolation
acceleration/deceleration for linear type rapid traverse.
If a value greater than 100000.0 is set, it is clamped to 100000.0.
If 0 is set, the following values are assumed:
1000.0 mm/sec/sec
100.0 inch/sec/sec
100.0 degrees/sec/sec
If 0 is set for all axes, before-interpolation acceleration/deceleration will not be
performed.
(2) Set the reference permissible acceleration of optimum torque
acceleration/deceleration.
If a value greater than 100000.0 is set, it is clamped to 100000.0.
If 0 is set, the following values are assumed:
1000.0 mm/sec/sec
100.0 inch/sec/sec
100.0 degrees/sec/sec
If 0 is set for all axes, optimum torque acceleration/deceleration will not be
performed.