B-63783EN-1/01 13.MEASUREMENT
- 1405 -
#7 #6 #5 #4 #3 #2 #1 #0
7206 2S8 2S7 2S6 2S5 2S4 2S3 2S2 2S1
[Input type] Parameter input
[Data type] Bit
2S1 to 2S8
2S1 to 2S82S1 to 2S8
2S1 to 2S8 A skip signal to be used for the G31.2 multi-step skip command is set.
Corresponding skip signal
Parameter High-speed skip signal
(HSS(No.7200#4)=1)
DI signal
(HSS(No.7200#4)=0)
2S1 HDI0 SKIP1
2S2 HDI1 SKIP2
2S3 HDI2 SKIP3
2S4 HDI3 SKIP4
2S5 HDI4
2S6 HDI5
2S7 HDI6
2S8 HDI7
0: A corresponding skip signal is invalid.
1: A corresponding skip signal is valid.
#7 #6 #5 #4 #3 #2 #1 #0
7207 3S8 3S7 3S6 3S5 3S4 3S3 3S2 3S1
[Input type] Parameter input
[Data type] Bit
3S1 to 3S8
3S1 to 3S83S1 to 3S8
3S1 to 3S8 A skip signal to be used for the G31.3 multi-step skip command is set.
Corresponding skip signal
Parameter High-speed skip signal
(HSS(No.7200#4)=1)
DI signal
(HSS(No.7200#4)=0)
3S1 HDI0 SKIP1
3S2 HDI1 SKIP2
3S3 HDI2 SKIP3
3S4 HDI3 SKIP4
3S5 HDI4
3S6 HDI5
3S7 HDI6
3S8 HDI7
0: A corresponding skip signal is invalid.
1: A corresponding skip signal is valid.