5.AUTOMATIC OPERATION B-63783EN-1/01
- 492 -
Signal
Manual absolute Signal
ABS<G004#5>
[Classification] Input signal
[Function] Turns off the manual absolute function.
[Operation] When this signal is set to 1, the control unit operates as follows:
Turns off the manual absolute function.
Manual absolute check Signal
MABSM<F004#5>
[Classification] Output signal
[Function] Notifies the PMC of the state of the manual absolute
signal.
[Output condition] This signal is set to 1 in the following case:
- When the manual absolute signal *ABS is set to 0
This signal is set to 0 in the following case:
- When manual absolute signal *ABSM is set to 1
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G004 ABS
F004 MABS
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
2409 ABS
[Input type] Parameter input
[Data type] Bit
# 3
# 3 # 3
# 3 ABS
ABSABS
ABS After manual intervention by manual absolute on, this bit specifies
whether the travel command path for absolute (G90) and for incrementa
(G91) are the same.
0: Different
1: Same (path for absolute)
Reference item
Series15i/150i-MB
Operator’s Manual
(Operation)
(B-63784EN-1)
II-5.3 Single block