7.FEEDRATE CONTROL/ACCELERATION AND DECELERATION CONTROL B-63783EN-1/01
- 718 -
In-position signals
INP1<F64#6>, INP2<F68#6>, ...
[Classification] Output signal
[Function] These signals indicate that the control axes are set to the in-position
condition.
They are provided for each control axis, and the number in the signal
name corresponds to the control axis number.
INPx
x : 1 - - - The 1st axis is set to the in-position condition.
2 - - - The 2nd axis is set to the in-position condition.
3 - - - The 3rd axis is set to the in-position condition.
: :
[Output condition] These signals turn to "1" in the following case :
- The acceleration/deceleration delay of the corresponding control
axis is zero and the servo error is within the specified allowance.
These signals turn to "0" in the following cases :
- The acceleration/deceleration delay of the corresponding control
axis is not zero.
- The servo error of the corresponding control axis exceeds the
specified allowance
NOTE
By setting parameter CIP (bit 0 of No. 1000), the
condition stating that the servo error must be within a
constant limit can be lifted.
- Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G008 *CSMZ
#7 #6 #5 #4 #3 #2 #1 #0
F064 INP1
The above addresses are the signal addresses for the first axis.
For the signal addresses for the second axis and subsequent axes, see
the Appendix A.1.