1.AXIS CONTROL B-63783EN-1/01
- 120 -
# 4
# 4 # 4
# 4 APZ
APZAPZ
APZ Indicates whether relative positioning of the machine position and
absolute-position detector is complete when an absolute-position detector
(absolute pulse coder) is used as the position detector.
0: Not complete
1: Complete
When an absolute-position detector is used: Set this bit to 0 when
primary at-site adjustment is done or the absolute pulse coder is replaced.
Then turn on the power, and set the origin of the absolute-position
detector by using, or example, manual reference position return.
Relative positioning of the machine position and absolute-position
detector is complete and APZx is automatically set to 1.
# 5
# 5 # 5
# 5 APC
APCAPC
APC Indicates whether the position detector is
0: a detector other than an absolute position detector.
1: an absolute position detector (absolute pulse coder).
#7 #6 #5 #4 #3 #2 #1 #0
1816 ACM DM3 DM2 DM1
[Input type] Parameter input
[Data type] Bitaxis
#1 to #3: DM1 to DM3 detection multiplier setting
Setting
DM3 DM2 DM1
Detection
multiplier
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
1/2
1
3/2
2
5/2
3
7/2
4
NOTE
1 To use flexible feed gears, set the respective DMR numerators
and denominators in parameter No. 1977 and No. 1978.
2 Set DM3 to DM1 to 111 for those axes to be subjected to spindle
positioning.