B-63783EN-1/01 5.AUTOMATIC OPERATION
- 541 -
#7 #6 #5 #4 #3 #2 #1 #0
1604 MNJ
[Input type] Parameter input
[Data type] Bitaxis
# 0
# 0 # 0
# 0 MNJ
MNJMNJ
MNJ Specifies whether both cutting feed acceleration/deceleration and jog fee
acceleration/deceleration are applied to manual handle interrupt or
simultaneous manual-automatic operation (interrupt type).
0: Both cutting feed acceleration/deceleration and jog feed
acceleration/deceleration are applied.
1: Only cutting feed acceleration/deceleration is valid, and jog feed
acceleration/deceleration is invalid.
Note
NOTE
1 When the parking signal is set to 1 during manual
feed based on the cutting axis interrupt type, manual
feed stops automatically.
2 When the cutting axis interrupt type is selected, and
automatic operation is switched from cutting to rapid
traverse or from rapid traverse to cutting, manual
feed stops automatically.
3 When the cutting axis interrupt type is selected, and
acceleration/deceleration before interpolation is
used, or operation is switched from threading to
cutting or from cutting to threading, manual feed
stops automatically.
4 When the cutting axis interrupt type is selected, and
single block operation is performed, feed by
automatic operation stops, but manual feed does not
stop. So, to start the next block, manual operation
must be stopped.
5 To use the simultaneous automatic and manual
operation function for manual handle feed as well,
the manual handle interrupt option is required.