9.SPINDLE FUNCTION B-63783EN-1/01
- 774 -
5846 Suffix for serial spindle (sub-spindle) display
[Input type] Parameter input
[Data type] Integerspindle
[Valid data range] 0 - 122
Set a suffix for spindle speed display on a screen such as the position display
screen.
Setting Character used as suffix
0, 32 Blank
1 to 9, 48 to 57 Numeric 0 to 9
65 to 90 Uppercase letter A to Z
97 to 122 Lowercase letter a to z
5850 Spindle number to be selected upon power-up/reset
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 4
Set a spindle number to be selected upon power-up/reset.
A selected spindle is used as:
- Spindle displayed on a screen such as the position display screen and program
check screen
- Spindle used for an S command, feed per revolution, constant surface speed
control, threading, canned cycles, rigid tapping, and spindle speed detection
NOTE
To rewrite this parameter during automatic operation, always use
a non-buffered M code set in parameter Nos. 2411 to 2420 so
that rewriting is performed in the non-buffering state.