1.AXIS CONTROL B-63783EN-1/01
- 136 -
• AMPLIFIER
The amplifier type display consists of the letter A, which
stands for "amplifier", a number that indicates the placing of
the amplifier, as counted from that nearest to the CNC, and a
letter such as L (first axis), M (second axis) or N (third axis)
indicating the placing of the axis in the amplifier.
• The following items are displayed as amplifier information:
- SERIES : servo amplifier series
- UNIT : servo amplifier unit type
- CUR. : maximum rating current
• AXIS No.
The axis number of each controlled axis specified in
parameters (Nos. 1080 to 1089) is displayed. If a number
specified in these parameters falls outside the range of
between 1 and the maximum number of controlled axes, 0 is
displayed. In automatic setting, the axis number of a
controlled axis connected to each servo amplifier is entered
in this field.
• NAME
The axis name assigned to a parameter (No. 1020)
corresponding to a particular controlled axis number is
displayed. If the controlled axis number is 0, - is displayed.
• The following items are displayed as pulse module
information:
- PULSE MOD.
This display consists of the letter M, which stands for
"pulse module", and a number indicating the placing of
the pulse module, as counted from that nearest to the
CNC.
-TYPE
This display is a letter indicating the type of the pulse
module.
- PCB ID
This display consists of four digits indicating the pulse
module ID (hexadecimal).
- Edition
The edition of the pulse module is displayed.
- Function
For a separate detector module (eight axes),
"DETECTOR (8AXES)" is displayed. For a separate
detector module (four axes), "DETECTOR (4AXES)"