B-63783EN-1/01 5.AUTOMATIC OPERATION
- 489 -
Signal
Single block signal
SBK<G004#3>
[Classification] Input signal
[Function] Enables single block operation.
[Operation] When this signal is set to 1, single block operation is performed. When
this signal is set to 0, normal operation is performed.
Single block check signal
MSBK<F004#3>
[Classification] Output signal
[Function] Notifies the PMC of the state of the single block signal.
[Output condition] This signal is set to 1 in the following case:
- When single block signal SBK is set to 1
This signal is set to 0 in the following case:
- When single block signal SBK is set to 0
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G004 SBK
F004 MSBK
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
0010 SBO SBC SBM SB8 SB7
[Input type] Setting input
[Data type] Bit
# 3 SB7 Specifies whether to stop after each block of custom macro statements in
programs O7000 to O7999.
0: Do not stop after each block.
1: Stop after each block.
Note)
This bit is used to check programs O7000 to O7999 containing custom
macro statements.
#4 SB8 Specifies whether to stop after each block of custom macro statements in
programs O8000 to O8999.
0: Do not stop after each block.
1: Stop after each block.
Note)
This bit is used to check programs O8000 to O8999 containing custom
macro statements.